← Projects & Proven Results
CSR Hebel · Safety Upgrades

Controlled Access.
Coordinated Safety.

A major upgrade to gated access and safety controls across three crane operating areas, delivered during CSR Hebel’s four-week Christmas shutdown.

Safety UpgradesManufacturingShutdown Delivery
Explore The Case Study
Zone Safety Panel & Gate Interface
4 WeeksChristmas Shutdown Window
27 PeopleProject Team
12-Hour DaysShutdown Delivery
3 Main AreasConnected By Crane Movement
The Brief

Three Operating Areas.
One Shared Crane Route.

Zone Safety Panel

CSR Hebel’s crane transferred parts between three large operating areas, creating an interface between overhead material movement and people accessing the plant.

ACS began by assessing the work areas and access routes. The upgrade brought together mechanical access measures and electrical safety controls: gated pathways, safety sensors and a safety PLC to coordinate the response to access or detection events.

A 27-person team worked 12-hour days within the four-week Christmas shutdown window. The focus was to better control access and bring the relevant equipment to a safe stop when a safety input was triggered.

Client
CSR Hebel
Industry
Manufacturing
Category
Safety Upgrades
Delivery
Christmas Shutdown
Scope
Gated Access, Safety Sensors & Safety PLC Controls
The Plant Environment

A Wider View.
Connected Operating Areas.

Views across the plant show the scale of the operating areas and the relationship between crane movement, equipment and access routes.

Upgrade Approach

Assess The Access.
Connect The Safety Response.

Assess The Areas

Review the crane route, the three main operating areas and the points where people needed access.

Control The Pathways

Provide gates at pathway access points as part of the mechanical measures around the operating areas.

Integrate Safety Inputs

Use a safety PLC with gate and sensor inputs to coordinate the electrical safety response.

Stop On A Safety Trigger

Configure the safety response so an access or sensor trigger brings the relevant crane and plant movement to a safe stop.

Project overview of the safety approach.

Gate Or Sensor TriggerSafety PLCControlled Stop Of Relevant Movement
Mechanical Access Measures

Gated Pathways.
Clear Access Points.

The pathway gates formed the physical access measures around the crane areas. Local controls and indicators provided a visible interface at the access points.

Electrical Safety Controls

Field Inputs.
A Coordinated Stop Response.

The safety PLC and connected inputs brought the access measures into the electrical control system. A triggered safety input initiated the response needed to stop the relevant movement, helping reduce exposure to the crane’s operating area.

Shutdown Delivery

A Defined Window.
A Coordinated Team.

The Christmas shutdown provided four weeks to carry out a major upgrade across large, interconnected operating areas.

27-Person Team

A substantial site team supported the mechanical access work and electrical safety installation within the shutdown programme.

12-Hour Days

The team worked extended days to progress the upgrade during the available shutdown period.

Connected Work Areas

Coordination had to consider the crane’s travel across all three areas alongside the people, pathways and access points below.

Project Outcome

Access Measures And Controls.
Working Together.

ACS delivered a major safety upgrade combining gated pathways with safety PLC control across the crane operating areas.

Better Controlled Access

Gates provided defined access points around the crane and connected work areas.

Safety-Triggered Stopping

Safety input triggers were linked to stopping the relevant equipment movement, supporting risk reduction where people and machinery interact.

Shutdown-Focused Delivery

The mechanical and electrical work was coordinated within the four-week Christmas shutdown programme.

Plan Your Safety Upgrade

Protecting Access.
Coordinating The Controls.

Talk to ACS about machinery safety upgrades, access control and electrical safety integration planned around your shutdown window.

Discuss Your Safety Upgrade